CGYTB - 02003C HI-TECH CIR COOLER, ELECTRONICAL- (SUPDAT)

  • MSDS: CGYTB
  • Manufacturer: SHERWIN WILLIAMS CO
  • Product Name: 02003C HI-TECH CIR COOLER, ELECTRONICAL- (SUPDAT)
  • National Stock Number: 6850-00N078966
Product Identification

Product ID:02003C HI-TECH CIR COOLER, ELECTRONICAL- (SUPDAT)
MSDS Date:02/01/1995
FSC:6850
NIIN:00N078966
MSDS Number: CGYTB

Responsible Party
SHERWIN-WILLIAMS CO
31500 SOLON RD
SOLON, OH 44139
US

Emergency Phone: 216-292-7400

Info Phone: 800-777-2966

Cage: DO642

Contractor
SHERWIN-WILLIAMS DIVERSIFIED BRANDS, INC.
BEDFORD HEIGHTS, OH 44146 US

Telephone: 216-292-7400 OR 216-595-8634

Cage: 09800

Ingredients

METHANE, CHLORODIFLUORO-; (CHLORODIFLUOROMETHANE) (SARA

CAS: 75-45-6

RTECS: PA6390000

Fraction By Weight: 100%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM


HEAT FROM SUNLIGHT, RADIATORS, STOVES,

RTECS: 9999999ZZ


BURST. DO NOT TAKE INTERNALLY. KEEP OUT OF THE REACH

RTECS: 9999999ZZ


USE ONLY W/ADEQ VENT. AVOID BRTHG VAPOR &

RTECS: 9999999ZZ


TO OSHA STANDARDS 1910.94, 1910.107, 1910.108.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CHLOROFLUOROCARBON (CFR) MATLS HAVE
PRDCED SENSIT OF THE MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS &
COULD HAVE A SIMILAR EFT IN HUMANS. ADRENOMIMETICS (EG,
EPINEPHRINE) MAY BE CONTRA-INDICATED EXCEPT FOR LIFE-SUSTAINING
USES IN HUMANS ACUTELY/CHRONICALLY EXPOSED TO CFCS . IRRIT OF EYES,
SKIN & (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: RESPIRATORY SYS. MAY CAUSE NERVOUS
SYS DEPRESS. EXTREME OVEREXP MAY RSLT IN UNCON & POSS DEATH. HDCH,
DIZZ, NAUS & LOSS OF COORD ARE INDICATIONS OF EXCESS EXPOS TO
VAPS/SPRAY MISTS. REDNESS & ITCHING OR BURNING SENSATION MAY
INDICATE EYE/EXCESS SKIN EXPOS. PRLNGD OVEREXP TO SOLVS LISTED IN
INGRED (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL: REMOVE FROM EXPOSURE. RESTORE BREATHING. KEEP WARM &
QUIET. SKIN: WASH AFFECTED AREA THOROUGHLY WITH SOAP & WATER.
REMOVE CONTAMINATED CLOTHING & LAUNDER BEFORE REUSE. EYES: FLUSH
WITH LARGE AM OUNTS OF WATER FOR AT LEAST 15 MINUTES.GET MED ATTN.
INGEST: NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. DO
NOT INDUCE VOMITING. GIVE SEVERAL GLASSES OF WATER. SEEK MED ATTN.

Fire Fighting

Flash Point Method:PMCC
Flash Point:>200F,>93C
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:WEAR NIOSH APPRVD PRESS DEMAND SCBA & FULL
PROT EQUIP . WATER SPRAY MAY BE INEFTIVE. IF WATER IS USED, FOG
NOZZS ARE PREF. WATER MAY BE USED TO (SUPDAT)
Unusual Fire/Explosion Hazard:THERMAL DECOMP PROD MAY INCL CHLORIDE,
FLOURIDES & PHOSGENE . CLOSED CNTNRS MAY EXPLODE (DUE TO THE
BUILD-UP OF PRESSURE) WHEN EXPOSED TO EXTREME HEAT.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DURING USE & UNTIL ALL VAPS ARE GONE:
KEEP AREA VENTILATED. CONTENTS UNDER PRESS. DO NOT PUNCTURE,
INCINERATE OR EXPOSE TO TEMP ABOVE 120F. (ING 3)
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN GEN VICIN OF
ARC WELDING, OPEN FLAMES OR HOT SURFS. HEAT &/OR UV RADIA MAY CAUSE
FORM OF HCL &/OR PHOSGENE . INTENTIONAL MISUSE BY DELIB CONC &
INHAL CON TENTS CAN BE HARMFUL/FATAL. (ING 5)

Exposure Controls

Respiratory Protection:IF PERSONAL EXPOSURE CANNOT BE CONTROLLED BELOW
APPLICABLE LIMITS BY VENTILATION, WEAR A PROPERLY FITTED ORGANIC
VAPOR/PARTICULATE RESPIRATORY APPROVED BY NIOSH FOR PROTECTION
AGAINST MATERIALS LISTED IN INGREDIENT SECTION.
Ventilation:LOCAL EXHAUST PREF. GEN EXHAUST ACCEPTABLE IF EXPOS TO
MATLS IS MAINTAINED BELOW APPLIC EXPOSURE LIMITS. REFER (ING 6)
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO: ELECTRONIC PRODUCTS. FIRE FIGHT PROC: COOL
CLSD CNTNRS TO PVNT PRESS BUILD-UP & POSS AUTOIGNIT OR EXPLO WHEN
EXPOSED TO EXTREME HEAT. EFTS OF OVEREXP: SECTION MAY CAUSE ADVER
SE EFTS TO LIVER & URINARY SYSTEMS. REPORTS HAVE ASSOC RPTD &
PRLNGD OVEREXP TO SOLVS W/PERM BRAIN & NERVOUS SYS DAMAGE.

Chemical Properties

Boiling Pt:B.P. Text:>165F,>74C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Evaporation Rate & Reference:FASTER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CHLORIDES, FLUORIDES AND PHOSGENE . BY
FIRE: CARBON DIOXIDE, CARBON MONOXIDE.

Disposal

Waste Disposal Methods:WASTE FROM THIS PRODUCT IS NOT HAZARDOUS AS
DEFINED UNDER RCRA 40 CFR 261. DO NOT INCINERATE. DEPRESSURIZE
CONTAINER. DISPOSE OF I/A/W FEDERAL, STATE AND LOCAL REGULATIONS
REGARDING POLLUTION.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.